User ManualThis manual MUST be given to the user of the product.BEFORE using this product, read this manual and save for future reference.ENInvacare®M
5 GENERAL GUIDELINESInvacare®MA60 Series 10 Part No 11481375 General Guidelines5.1 General GuidelinesContraindicationsWARNINGDO NOT use this produc
5 GENERAL GUIDELINESPart No 1148137 11 Invacare®MA60 SeriesInstallationWARNINGThe MA60 and MA65 systems (including bariatric and raised side rail) is
5 GENERAL GUIDELINESInvacare®MA60 Series 12 Part No 11481375.2 Entrapment May OccurWARNINGPatient entrapment with bed side rails may cause injury or
5 GENERAL GUIDELINESPart No 1148137 13 Invacare®MA60 SeriesFire HazardDANGERSmokingDO NOT SMOKE while using this device. This system uses room air fo
5 GENERAL GUIDELINESInvacare®MA60 Series 14 Part No 11481375.3 ElectricalDANGERElectrical shock hazard. DO NOT remove cover. Refer to qualified servi
6 OPERATIONPart No 1148137 15 Invacare®MA60 Series6 Operation6.1 Installing the Powered MattressCAUTIONThe control unit and mattress on the MA60 se
6 OPERATIONInvacare®MA60 Series 16 Part No 11481371. Remove the original foam mattress from the bed.2. If necessary, lower the side rails to facilitat
6 OPERATIONPart No 1148137 17 Invacare®MA60 Series6.2 Installing the Bed Side RailsWARNINGPatient entrapment with bed side rails may cause injury or
6 OPERATIONInvacare®MA60 Series 18 Part No 11481376.3 Installing the Control Unit1. Pull out the bed hook on the back of the control unit. 2. Place th
6 OPERATIONPart No 1148137 19 Invacare®MA60 SeriesFIGURE2 Connecting the HoseHose ConnectorHoseControl Unit ConnectorsTab
Invacare®MA60 Series 2 Part No 1148137© 2011 Invacare Corporation. All rights reserved. Republication, duplication or modification in whole or in par
6 OPERATIONInvacare®MA60 Series 20 Part No 11481376.5 Connecting the Power Cord1. Examine the hospital grade power cord supplied with the control unit
6 OPERATIONPart No 1148137 21 Invacare®MA60 Series6.6 Using the Front PanelFIGURE3 Using the Front PanelDETAIL “B” - MA65 SERIES FRONT PANELPower B
6 OPERATIONInvacare®MA60 Series 22 Part No 1148137Power Button1. To turn the control unit on or off, press and release the Power button ( ).Alternatin
6 OPERATIONPart No 1148137 23 Invacare®MA60 Series3. Read the LCD Display. The LCD Display will show:• 0 if the current setting is 0 (2 mmHg).• 5 if t
6 OPERATIONInvacare®MA60 Series 24 Part No 1148137Fowler ButtonManual Mode1. Press the Fowler button ( ) to activate the patient fowler mode.Automatic
6 OPERATIONPart No 1148137 25 Invacare®MA60 Series5. Perform one of the following:• Cancel - Press the Fowler button to exit Fowler Transmitter Setup
6 OPERATIONInvacare®MA60 Series 26 Part No 1148137• Low Air Loss Mode - In this mode, the mattress goes into on-demand low air loss relief mode.Lock/A
6 OPERATIONPart No 1148137 27 Invacare®MA60 Series6.7 Powering Up the System1. Turn on the power to the system by pressing the Power button on the con
6 OPERATIONInvacare®MA60 Series 28 Part No 11481379. Verify that the patient has not bottomed out by performing the following steps:A. Ensure that the
6 OPERATIONPart No 1148137 29 Invacare®MA60 Series6.10 Transferring Patient From/To a Wheelchair1. Engage the wheel locks of the bed. Refer to the own
2 GENERALPart No 1148137 3 Invacare®MA60 Series2 General2.1 SymbolsWarningsSignal words are used in this manual and apply to hazards or unsafe pract
6 OPERATIONInvacare®MA60 Series 30 Part No 1148137FIGURE4 Preparing for CPR Procedure6.12 About Power Outage and TransportationIf the hoses remain
7 MAINTENANCE AND TROUBLESHOOTINGPart No 1148137 31 Invacare®MA60 Series7 Maintenance and Troubleshooting7.1 Cleaning the System1. Remove the beddin
7 MAINTENANCE AND TROUBLESHOOTINGInvacare®MA60 Series 32 Part No 11481378. Perform the following steps to clean the mattress cover:A. Using a clean sp
7 MAINTENANCE AND TROUBLESHOOTINGPart No 1148137 33 Invacare®MA60 SeriesStoring the System1. Ensure that the control unit is off and disconnect the po
7 MAINTENANCE AND TROUBLESHOOTINGInvacare®MA60 Series 34 Part No 11481377.2 TroubleshootingPROBLEM CAUSE SOLUTIONMattress not inflatingNot alternating
NOTESPart No 1148137 35 Invacare®MA60 SeriesNOTES
Invacare CorporationUSAOne Invacare WayElyria, Ohio USA44036-2125800-333-6900Canada570 Matheson Blvd E Unit 8Mississauga OntarioL4Z 4G4 Canada800-668-
2 GENERALInvacare®MA60 Series 4 Part No 11481372.2 Limited WarrantyPLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICA
CONTENTSPart No 11481375 Invacare®MA60 Series2 GENERAL 3Symbols ...
4 OVERVIEWInvacare®MA60 Series 6 Part No 11481374 Overview4.1 Label LocationDANGER-EXPLOSION HAZARD: DO NOT use in the presence of flammable anesthe
4 OVERVIEWPart No 1148137 7 Invacare®MA60 Series4.2 Typical Product ParametersElectrical ParametersMA65 Power unit is also used on MA65B42, MA65B48,
4 OVERVIEWInvacare®MA60 Series 8 Part No 1148137Performance ParametersMA60/MA65WEIGHT CAPACITYSTANDARD MATTRESS (36 INCH):BARIATRIC MATTRESS:42 INCH M
4 OVERVIEWPart No 1148137 9 Invacare®MA60 SeriesMechanical ParametersEnvironmental ParametersMA60 MA65CONTROL UNITDIMENSIONS (L X W X H):15” x 6.5” x
Comments to this Manuals