Invacare MA90Z User Manual

Browse online or download User Manual for Sports and recreation Invacare MA90Z. Invacare MA90Z User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
User Manual
This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference.
EN
Invacare
®
MA90Z Series Mattresses
MA90Z Lateral Rotation with Alternating Pressure and On-Demand Low Air Loss System
MA90ZB42 Lateral Rotation with Alternating Pressure and On-Demand Low Air Loss Bariatric 42”
MA90ZB48 Lateral Rotation with Alternating Pressure and On-Demand Low Air Loss Bariatric 48”
Invacare
®
MA95Z Series Mattresses
MA95Z Lateral Rotation with Alternating Pressure and True Low Air Loss System
MA95ZB42 Lateral Rotation with Alternating Pressure and True Low Air Loss Bariatric 42”
MA95ZB48 Lateral Rotation with Alternating Pressure and True Low Air Loss Bariatric 48”
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - User Manual

User ManualThis manual MUST be given to the user of the product.BEFORE using this product, read this manual and save for future reference.EN Invacare®

Page 2 - 2 Part No 1148139

3 SAFETYInvacare® MA90Z Series Mattresses 10 Part No 11481393 Safety3.1 General GuidelinesContraindicationsWARNINGDO NOT use this product or any av

Page 3 - 3 Invacare

3 SAFETYPart No 1148139 11 Invacare® MA90Z Series MattressesInstallationWARNINGThe MA90Z and MA95Z series (including bariatric) is recommended to be

Page 4 - 1 General

3 SAFETYInvacare® MA90Z Series Mattresses 12 Part No 1148139Entrapment May OccurWARNINGPatient entrapment with bed side rails may cause injury or dea

Page 5 - 1 GENERAL

3 SAFETYPart No 1148139 13 Invacare® MA90Z Series MattressesFire HazardElectricalDANGERSmokingDO NOT SMOKE while using this device. This system uses

Page 6 - 2 Overview

4 OPERATIONInvacare® MA90Z Series Mattresses 14 Part No 11481394 Operation4.1 Installing the Mattress Replacement SystemCAUTIONThe control unit and

Page 7 - MA90Z MA95Z

4 OPERATIONPart No 1148139 15 Invacare® MA90Z Series Mattresses1. Remove the original foam mattress from the bed.2. If necessary, lower the side rails

Page 8

4 OPERATIONInvacare® MA90Z Series Mattresses 16 Part No 11481394.2 Installing the Side Rails4.3 Installing the Power Unit1. Pull out the bed hook on

Page 9 - MA90Z/MA95Z

4 OPERATIONPart No 1148139 17 Invacare® MA90Z Series Mattresses1. Locate the hose at the foot end of the mattress.2. Locate the control unit connector

Page 10 - 3 Safety

4 OPERATIONInvacare® MA90Z Series Mattresses 18 Part No 11481394.5 Connecting the Power Cord1. Examine the hospital grade power cord supplied with the

Page 11 - 3 SAFETY

4 OPERATIONPart No 1148139 19 Invacare® MA90Z Series Mattresses4.6 Using the Front PanelFIGURE4 Using the Front PanelDETAIL “B” - MA95Z POWER UNIT

Page 12

Invacare® MA90Z Series Mattresses 2 Part No 1148139© 2011 Invacare Corporation. All rights reserved. Republication, duplication or modification in wh

Page 13

4 OPERATIONInvacare® MA90Z Series Mattresses 20 Part No 1148139Power Button1. To turn the control unit on or off, press and release the Power button (

Page 14 - 4 Operation

4 OPERATIONPart No 1148139 21 Invacare® MA90Z Series MattressesRotation Button (MA95Z Power Unit)1. Press the Rotation button ( ) to select Static mod

Page 15 - 4 OPERATION

4 OPERATIONInvacare® MA90Z Series Mattresses 22 Part No 11481393. Use the Select button to move the pointer to the times or attributes available for t

Page 16

4 OPERATIONPart No 1148139 23 Invacare® MA90Z Series MattressesAutomatic Wireless Fowler Manual Operation of the Fowler1. Press the Select button ( )

Page 17

4 OPERATIONInvacare® MA90Z Series Mattresses 24 Part No 1148139iii. Perform one of the following:• Cancel - Press the Turn Angle button to exit Fowler

Page 18

4 OPERATIONPart No 1148139 25 Invacare® MA90Z Series MattressesMax Inflate Button (MA95Z Power Unit)1. Press the Max Inflate button ( ) to select the

Page 19

4 OPERATIONInvacare® MA90Z Series Mattresses 26 Part No 1148139Power Fail LEDIn the event of power outage, an alarm sounds and the Power Fail LED flas

Page 20

4 OPERATIONPart No 1148139 27 Invacare® MA90Z Series Mattresses4.8 Placing the Patient on the Mattress1. Press the Mode button or Max Inflate button t

Page 21 - FUNCTION DESCRIPTION

4 OPERATIONInvacare® MA90Z Series Mattresses 28 Part No 11481394.9 Transferring Patient From/To a Gurney1. Engage the wheel locks of the bed. Refer to

Page 22

4 OPERATIONPart No 1148139 29 Invacare® MA90Z Series Mattresses4.11 Preparing for CPR Procedure1. Perform one of the following:• MA90Z Power Unit - Pr

Page 23

CONTENTSPart No 11481393 Invacare® MA90Z Series Mattresses1 GENERAL 4Warnings...

Page 24

4 OPERATIONInvacare® MA90Z Series Mattresses 30 Part No 1148139FIGURE5 Preparing for CPR ProcedureConnector CoverControl Unit ConnectorsMA95Z, MA95

Page 25

5 MAINTENANCE AND TROUBLESHOOTINGPart No 1148139 31 Invacare® MA90Z Series Mattresses5 Maintenance and Troubleshooting5.1 Cleaning the System1. Remo

Page 26

5 MAINTENANCE AND TROUBLESHOOTINGInvacare® MA90Z Series Mattresses 32 Part No 1148139• If blood is not present, remove any soil from the cover with pa

Page 27

5 MAINTENANCE AND TROUBLESHOOTINGPart No 1148139 33 Invacare® MA90Z Series Mattresses10. Perform the following steps to clean the mattress components

Page 28

5 MAINTENANCE AND TROUBLESHOOTINGInvacare® MA90Z Series Mattresses 34 Part No 1148139FIGURE1 Changing the FilterFilter CoverScrews

Page 29

5 MAINTENANCE AND TROUBLESHOOTINGPart No 1148139 35 Invacare® MA90Z Series Mattresses5.3 TroubleshootingPROBLEM CAUSE SOLUTIONMattress not inflatingNo

Page 30

Invacare CorporationUSAOne Invacare WayElyria, Ohio USA44036-2125800-333-6900Canada570 Matheson Blvd E Unit 8Mississauga OntarioL4Z 4G4 Canada800-668-

Page 31 - 31 Invacare

1 GENERALInvacare® MA90Z Series Mattresses 4 Part No 11481391 General1.1 WarningsSignal words are used in this manual and apply to hazards or unsafe

Page 32 - 32 Part No 1148139

1 GENERALPart No 1148139 5 Invacare® MA90Z Series Mattresses1.2 Limited WarrantyPLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERA

Page 33 - 33 Invacare

2 OVERVIEWInvacare® MA90Z Series Mattresses 6 Part No 11481392 Overview2.1 Label LocationDANGER-EXPLOSION HAZARD: DO NOT use in the presence of flam

Page 34 - Filter Cover

2 OVERVIEWPart No 1148139 7 Invacare® MA90Z Series Mattresses2.2 Typical Product ParametersElectrical ParametersPerformance ParametersMA90Z power uni

Page 35 - PROBLEM CAUSE SOLUTION

2 OVERVIEWInvacare® MA90Z Series Mattresses 8 Part No 1148139PRESSURE ZONE:2MAXIMUM FLOW:50 ± 15 LPM 1275 ± 100 LPMMAXIMUM PRESSURE:35 ± 5 mmHgMAXIMUM