User ManualThis manual MUST be given to the user of the product.BEFORE using this product, read this manual and save for future reference.EN Invacare®
3 SAFETYInvacare® MA90Z Series Mattresses 10 Part No 11481393 Safety3.1 General GuidelinesContraindicationsWARNINGDO NOT use this product or any av
3 SAFETYPart No 1148139 11 Invacare® MA90Z Series MattressesInstallationWARNINGThe MA90Z and MA95Z series (including bariatric) is recommended to be
3 SAFETYInvacare® MA90Z Series Mattresses 12 Part No 1148139Entrapment May OccurWARNINGPatient entrapment with bed side rails may cause injury or dea
3 SAFETYPart No 1148139 13 Invacare® MA90Z Series MattressesFire HazardElectricalDANGERSmokingDO NOT SMOKE while using this device. This system uses
4 OPERATIONInvacare® MA90Z Series Mattresses 14 Part No 11481394 Operation4.1 Installing the Mattress Replacement SystemCAUTIONThe control unit and
4 OPERATIONPart No 1148139 15 Invacare® MA90Z Series Mattresses1. Remove the original foam mattress from the bed.2. If necessary, lower the side rails
4 OPERATIONInvacare® MA90Z Series Mattresses 16 Part No 11481394.2 Installing the Side Rails4.3 Installing the Power Unit1. Pull out the bed hook on
4 OPERATIONPart No 1148139 17 Invacare® MA90Z Series Mattresses1. Locate the hose at the foot end of the mattress.2. Locate the control unit connector
4 OPERATIONInvacare® MA90Z Series Mattresses 18 Part No 11481394.5 Connecting the Power Cord1. Examine the hospital grade power cord supplied with the
4 OPERATIONPart No 1148139 19 Invacare® MA90Z Series Mattresses4.6 Using the Front PanelFIGURE4 Using the Front PanelDETAIL “B” - MA95Z POWER UNIT
Invacare® MA90Z Series Mattresses 2 Part No 1148139© 2011 Invacare Corporation. All rights reserved. Republication, duplication or modification in wh
4 OPERATIONInvacare® MA90Z Series Mattresses 20 Part No 1148139Power Button1. To turn the control unit on or off, press and release the Power button (
4 OPERATIONPart No 1148139 21 Invacare® MA90Z Series MattressesRotation Button (MA95Z Power Unit)1. Press the Rotation button ( ) to select Static mod
4 OPERATIONInvacare® MA90Z Series Mattresses 22 Part No 11481393. Use the Select button to move the pointer to the times or attributes available for t
4 OPERATIONPart No 1148139 23 Invacare® MA90Z Series MattressesAutomatic Wireless Fowler Manual Operation of the Fowler1. Press the Select button ( )
4 OPERATIONInvacare® MA90Z Series Mattresses 24 Part No 1148139iii. Perform one of the following:• Cancel - Press the Turn Angle button to exit Fowler
4 OPERATIONPart No 1148139 25 Invacare® MA90Z Series MattressesMax Inflate Button (MA95Z Power Unit)1. Press the Max Inflate button ( ) to select the
4 OPERATIONInvacare® MA90Z Series Mattresses 26 Part No 1148139Power Fail LEDIn the event of power outage, an alarm sounds and the Power Fail LED flas
4 OPERATIONPart No 1148139 27 Invacare® MA90Z Series Mattresses4.8 Placing the Patient on the Mattress1. Press the Mode button or Max Inflate button t
4 OPERATIONInvacare® MA90Z Series Mattresses 28 Part No 11481394.9 Transferring Patient From/To a Gurney1. Engage the wheel locks of the bed. Refer to
4 OPERATIONPart No 1148139 29 Invacare® MA90Z Series Mattresses4.11 Preparing for CPR Procedure1. Perform one of the following:• MA90Z Power Unit - Pr
CONTENTSPart No 11481393 Invacare® MA90Z Series Mattresses1 GENERAL 4Warnings...
4 OPERATIONInvacare® MA90Z Series Mattresses 30 Part No 1148139FIGURE5 Preparing for CPR ProcedureConnector CoverControl Unit ConnectorsMA95Z, MA95
5 MAINTENANCE AND TROUBLESHOOTINGPart No 1148139 31 Invacare® MA90Z Series Mattresses5 Maintenance and Troubleshooting5.1 Cleaning the System1. Remo
5 MAINTENANCE AND TROUBLESHOOTINGInvacare® MA90Z Series Mattresses 32 Part No 1148139• If blood is not present, remove any soil from the cover with pa
5 MAINTENANCE AND TROUBLESHOOTINGPart No 1148139 33 Invacare® MA90Z Series Mattresses10. Perform the following steps to clean the mattress components
5 MAINTENANCE AND TROUBLESHOOTINGInvacare® MA90Z Series Mattresses 34 Part No 1148139FIGURE1 Changing the FilterFilter CoverScrews
5 MAINTENANCE AND TROUBLESHOOTINGPart No 1148139 35 Invacare® MA90Z Series Mattresses5.3 TroubleshootingPROBLEM CAUSE SOLUTIONMattress not inflatingNo
Invacare CorporationUSAOne Invacare WayElyria, Ohio USA44036-2125800-333-6900Canada570 Matheson Blvd E Unit 8Mississauga OntarioL4Z 4G4 Canada800-668-
1 GENERALInvacare® MA90Z Series Mattresses 4 Part No 11481391 General1.1 WarningsSignal words are used in this manual and apply to hazards or unsafe
1 GENERALPart No 1148139 5 Invacare® MA90Z Series Mattresses1.2 Limited WarrantyPLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERA
2 OVERVIEWInvacare® MA90Z Series Mattresses 6 Part No 11481392 Overview2.1 Label LocationDANGER-EXPLOSION HAZARD: DO NOT use in the presence of flam
2 OVERVIEWPart No 1148139 7 Invacare® MA90Z Series Mattresses2.2 Typical Product ParametersElectrical ParametersPerformance ParametersMA90Z power uni
2 OVERVIEWInvacare® MA90Z Series Mattresses 8 Part No 1148139PRESSURE ZONE:2MAXIMUM FLOW:50 ± 15 LPM 1275 ± 100 LPMMAXIMUM PRESSURE:35 ± 5 mmHgMAXIMUM
2 OVERVIEWPart No 1148139 9 Invacare® MA90Z Series MattressesMechanical ParametersEnvironmental ParametersMA90Z MA95ZCONTROL UNIT DIMENSIONS (L X W X
Comments to this Manuals